Milton-roy-mixing HELISEM RANGE VLA SERIES User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
Type A B C E F
2430S 388 - 12 200 165
2530S 388 - 12 200 165
3530S 388 - 12 200 165
4630S 425 - 12 200 165
5630S 425 - 12 200 165
Please consult us for any other request.
DIMENSIONS (MM)
SPECIFICATIONS
Type Rated power Rotation speed Maximum height Propeller diameter Propeller flowrate Weight Torque
(kW) (rpm) (mm) H (mm) D (m
3
/h) (Kg) (Nm)
2430S 0.37 1000 1500 128 69 20 7
2530S 0.75 1500 1500 128 104 20 9
3530S 0.75 1500 1500 140 136 20 9
4630S 1.5 1500 1500 160 203 27 20
5630S 1.5 1500 1000 200 396 27 20
The minimum height of the liquid at the top of the impeller is 300 mm.
It is necessary to respect a distance of 150 mm between the flange and the level of the liquid.
Ref: MRM8212201-06/09-Rev02-All rights reserved for modification without prior notice-non binding information
www.miltonroy.com
MILTON ROY MIXING
10, rue du bois Gasseau BP N°94
77212 AVON Cedex
FRANCE
Tel : +33 (0) 1.60.74.95.20
Fax : +33 (0) 1.60.74.95.29
www.miltonroymixing.com